O p e r a t i n g I n s t r u c t i o n s
OKTOPUS
®
GLASS-Jack
GL-CC 1200
Technical Documentation
BA 000 257
Page 11 of 28
1500 mm
2410 mm
2200 mm
2.4.1 Arrangement of suction pads
Fig. 5:
Arrangement of suction pads
Please contact the Wirth service team, if an arrangement of suction pads differing from figure
5 is required.
Always distribute the suction pads evenly on both vacuum circles! Non-
compliance with these instructions could, in case of a breakdown of a vac-
uum circuit, lead to the load suddenly dropping due to an uneven load dis-
tribution.
2.5 Operating conditions and restrictions
The suction areas of the glass elements to be handled with the OKTOPUS
®
GLASS-Jack
GL-CC 1200:
•
have to be airtight,
•
have to have an even, dry, oil-free and clean surface and
•
must not be covered with protective film!
11
00
m
m
Suction frame for flat glass panes,
without extensions, 8 suction pads
(WLL max. 800 kg)
Suction frame for flat glass panes,
with extensions, 12 suction pads
(WLL max. 1200 kg)
15
30
m
m
Vacuum circuit 2 (blue)
Vacuum circuit 1 (red)
10
00
m
m
Suction frame for curved glass panes,
20 suction pads
(WLL max. 1000 kg)