4.4 Electrics and electrical components
The OKTOPUS
®
GLASS-Jack GL-RN 400/600/800 is running with a maintenance-free lead-gel
battery (acidic). The battery casing is hermetically sealed.
Maintenance focuses on:
⇒
daily
inspection of the external electrical functions and alarm devices:
•
Alarm signal,
•
Signal light,
•
Alarm buzzer.
⇒
checking the charging level of the battery on the charge indicator (see fig. 8).
⇒
battery charging
A 24 V / 5 A charger for charging the battery is supplied by the OKTOPUS
®
system manu-
facturer (see fig. 19).
Fig. 19:
Battery charger (sample)
Before connecting the charger to the power supply, check whether appropri-
ate! The respective data of capacity you will find on the charger.
In case you want to use a charger other than the one belonging to the OK-
TOPUS
®
scope of supply, it becomes essential to contact the Wirth Service
Team in advance!
The battery has to be charged as follows:
•
Switch off the OKTOPUS
®
. For this turn the main switch to „OFF“ position!
•
Connect the charger plug to the battery socket for charging OKTOPUS
®
.
•
Connect the power plug of the charger to the power supply via socket to start the
charging procedure.
•
The charging is finished as soon as the yellow LED lights up permanently.
•
Proceed as follows to disconnect the charger from the OKTOPUS
®
:
1. Disconnect the charger from the power supply,
2. Separate the connection between charger and battery.
1 2 3 4 5
1 Charge plug charger
2 Yellow LED
3 Green LED
4 Battery charger
5 Main plug