4_
SHD-3000F2
INSTALLATION INSTRUCTIONS
1.
Select an installation position or place that can endure more than 4 times of the total weight
of the installation structure.
2.
At least 250mm or more of spare height is required above the
CEILING BOARD
.
3.
CEILING BOARD
’s thickness should be less than 40mm.
4.
Be sure to secure the SAFETY WIRE to avoid a product fall.
5.
If you want to attach the camera to the ADAPTOR, use the only provided SCREWS.
INSTALLATION
(INDOOR TYPE)
1.
Place the
TEMPLATE
on the
CEILING BOARD
and drill a guided hole.
❶
Remove the round filling (“C”) from the
TEMPLATE
.
➋
Place
TEMPLATE
A onto the
CEILING BOARD
to which you will attach the ceiling
mount ADAPTOR and drill a hole of Ø165mm in diameter.
See the figure below for the hole shape.
250mm 이상일 것
천장보드
40mm 이하일 것
More than 250mm
CEILING BOARD
Less than 40mm
Ø165mm
형판
천장 보드
Ø
165mm
TEMPLATE
CEILING BOARD