Operating instructions
- 15 -
3.6 Tangram GT11 / 12 internal Switch / Control tab
3.6.1 Modules tab
On the Tangram GT11 Control Tab you can maintain the modules:
In the left field there are the Modules / Slots identified by the Chassis / Switch.
3.6.2 Module Status and Settings
You can check and set the Modules on the Modules tab. You can switch them on /off
and can reset them remotely. Additional you can configure Module Redundancy (n+1):
3.6.3 n+1 Module Redundancy
You can check and set the Modules Redundancy mode of a module by choosing the
Redundancy mode (Master or Reserved) within that `Modules´ Tab column.
A module which should be secured has to be in `Master´ mode, the module which
should take the redundancy in case one of the Master modules fails has to be set to
´Reserved`. There is no mixing of different module types allowed / possible to apply
Module redundancy. If a problem is detected on a “Master” module the power is
automatically switched off and the `Reserved´ module is activated simultanously with
the Master config.
To revert the redundancy you have to switch on Power again for the replaced Module by
hand in this tab. The reserved module will go to reserved mode again and switch off its
own outputs when the new Module comes up again.
3.6.4 Module Redundancy status
You can see the Status of Module redundancy within the Redundancy status column.