MCR41/MCR42 User Manual
11
In the fourth screen are displayed the main audio information
In this screen are showed:
❶
the number of the receiver
❷
the Expander
❸
the max audio level
❹
an indication bar from -42 to 0 dB with step of 6dB
(0dB peak deviation ≥ 56KHz)
❺
the modulation level with the indicator of modulation
peak (when the indicator goes to 0dB, the square on the
right of the display become white for about 1 second to
highlight the peak occurred)
Pushing SEL button it’s possible to enable the Calibration Tone
and set the max audio level of the outputs:
-
LINE max lev: -8÷12 dBu (only for HW rev ≥ 21)
-
MIC max lev: -30÷10 dBu (only for HW rev ≥ 21)
-
LINE max lev: -18÷12 dBu (only for HW rev < 21)
-
AES max lev: -30÷0 dBFS
-
COM max lev: -18÷12 dBu (only with BPA42-PTT)
MAIN MENU
Infrared:
By activating the infrared, you can connect the MCR42 to
other devices (such as a UPK300)
Preset:
The preset menu has the following two submenus:
Restore
: that allows to reload 3 different presets
(PRESET_1, 2, 3) earlier saved or a Factory preset (a preset
load in the Wisycom factory)
Save
: that allows to save 3 different presets (PRESET_ 1, 2,
3)
Each saved preset consists of all user parameters indicated
in blue in the graphic on page 8 (
❶
❷
❸
❹
❺
❶
❷
❸
❺
Step 1dB