Operating instrutions
WITA Delta Plus UE 35A-XX PWM | UE 55A-XX PWM
28
8
Venting programme
Pressing the key for a longer period (> 5 sec) will start a venting program which lasts about 4,5
minutes. The display LED lights up green during this, and the program runs through several sta-
ges at different speeds and different lengths of time. The workflow can be terminated early by
pressing the key. The pump then returns to the previously selected mode of operation.
Description of the venting program:
Stage
Duration
III
15 sec.
I
30 sec.
III
15 sec.
I
30 sec.
II
60 sec.
off
30 sec.
II
30 sec.
I
10 sec.
III
5 sec.
I
5 sec.
III
5 sec.
I
5 sec.
II
5 sec.
off
5 sec.
II
5 sec.
I
5 sec.
Stage I
Stage II
Stage III
UE 35A PWM
950 UPM
1850 UPM
2600 UPM
UE 55A PWM
950 UPM
2250 UPM
3500 UPM
Total duration
approx. 260 sec.