Installation steps (critical doors and floors / without door function):
For increased functional security when installing in front of the door, the reception signals
(reference values) must be programmed into the light curtain when the door is open and the
area to be protected is clear.
•
The LIGI is installed as explained in the operating instructions, i.e. the transmitter is
connected as indicated in the table above (bottom row).
• When the door is open and the area to be protected is clear, the sync connection
between the transmitter and receiver is connected/hot-wired with 10-30 V DC
using a short filament for a very short period of time (less than 1s). Everything
else will now happen automatically.
•
If the previous step has been carried out correctly, the green LED on the receiver will
be continuously on and the red LED will flash. The reference values will then be pro-
grammed. It is essential to keep the area to be protected clear during this time. This
programming process will take 10s and the red LED will then go out.
Installation options
Notes
Installation in front of door
noncritical standard doors
(without door function)
Door and floor have matt surfaces.
Installation in front of door
critical doors; critical floors
(without door function)
Critical points:
Part or all of the door has a highly reflective
surface.
Increased functional safety can be achieved by
programming the signals when the door is open
(see descriptions below).
Summary of Contents for LIGI-10 FLEX Series
Page 17: ...Sensoric Sensoric GmbH Berlin www witt sensoric de 17 Sensoric 29 16 Mounting materials...
Page 21: ...Sensoric Sensoric GmbH Berlin www witt sensoric de 21 Sensoric...
Page 22: ...Sensoric Sensoric GmbH Berlin www witt sensoric de 22 Sensoric...
Page 23: ...Sensoric Sensoric GmbH Berlin www witt sensoric de 23 Sensoric...