31
ELECTRICAL CONNECTION
The installation of this appliance and the connection to the electrical network should be
entrusted only to an electrician perfectly to the fact of the normative regulations and which
respects them scrupulously.
Protection against the parts under tension must be ensured after the building-in.
The data of connection necessary are on the stickers place on the hob casing near the
connection box.
The connection to the main must be made using an earthed plug or via an omnipolar circuit
breaking device with a contact opening of at least 3 mm.
The electrical circuit must be separated from the network by adapted devices, for example:
circuit breakers, fuses or contactors.
If the appliance is not fitted with an accessible plug, disconnecting means must be
incorporated in the fixed installation, in accordance with the installation regulations.
The inlet hose must be positioned so that it does not touch any of the hot parts of the hob or
even.
CONNECTION OF THE HOB
For the various kinds of connection, use the brass bridges which are in the box next the terminal.
Caution!
- Connect always the earth wire.
- Respect the connection diagram.
- This device is intended for a supply of 230 V ~ 50/60 Hz
- The connection box is located underneath at the back of the hob casing. To open the cover use a
medium screwdriver. Place it in the slits and open the cover.
Country
Mains
Connection
Cable diameter
Cable
Protection
calibre
DK-S-FIN 230V~ 50/60Hz
1 Phase + N
3 x 2.5 mm²
H 05 VV - F
H 05 RR - F
25 A *
DK-S-FIN 400V~ 50/60Hz
2 N
4 x 1,5 mm²
H 05 VV - F
H 05 RR - F
16 A *
N
230V~ 50/60Hz
2 Phases
3 x 2,5 mm²
H 05 VV - F
H 05 RR - F
25 A *
( * ) calculated with the simultaneous factor following standard EN 60 335-2-6/1990
Summary of Contents for 6424300
Page 32: ...18053 0 ...