Revision: 02
Ethernet/IP: LED MS indicates the module state
Stauts
LED
LED MS
Meaning
Off
The bus module has no power supply or
is defective
Flash:
Green,
Red,
Green
The bus module is performing its power
up testing
Flash:
Green
Standby: The bus module is not
configured (e. g. no network cable
connected)
Flash: Red
The bus module is in fault state but fault
can be reset
Constant:
Red
The bus module is in fault state and
fault can’t be reset. Restart drive.
Constant:
Green
The bus module is operating correctly.
Table 10: LED codes MS Ethernet/IP
PROFINET: LED MS (SF) indicates the system failure
Status
LED
LED MS
Meaning
Off
The device has no error (or has no power
supply or is defective).
Flash: Red
(1 Hz, 3 s)
DCP signal service is initiated via the
bus.
Constant:
Red
Watchdog timeout; channel, generic or
extended diagnosis present; system error
Table 11: LED codes MS PROFINET
7.3.3 LED codes NS
LED NS is dependent on the bus system type.
EtherCAT: LED NS indicates the error state
Status LED
LED NS
Meaning
Off
The device has no error (or has no
power supply or is defective)
Flash: Red
(2,5 Hz)
Invalid configuration: Maybe the
master has sent a configuration which
can not be activated by the slave
Flash: Red
(single flash)
Local error: The slave changed its
state independent. Maybe a host
watchdog timeout or synchronisation
error occured
Flash: Red
(double
flash)
Process data watchdog timeoug
Table 12: LED codes NS EtherCAT