Ethernet/IP: LED NS indicates the fieldbus state
Status
LED
LED NS
Meaning
Off
The bus module has no IP addrress (or
has no power supply or is defective)
Flash:
Green,
Red, Off
The bus module is performing ist power
up testing
Flash:
Green
An IP address is configured but no CIP
connection is active
Flash:
Red
An IP address is configured but the
timeout limit was exceeded
Constant:
Red
The bus module has detected that its IP
address is already in use
Constant:
Green
The bus has an IP address ant at least
one CIP connection is active (without
timeout)
Table 13: LED codes NS Ethernet/IP
PROFINET: LED NS (BF) indicates the bus failure
Status
LED
LED NS
Meaning
Off
The device has no error (or has no
power supply or is defective).
Flash: Red
(2 Hz)
No data exchange
Constant:
Red
No configuration; or low speed physical
link; or no physical link
Table 14: LED codes NS PROFINET