cyber
®
simco
®
drive 2 operating manual
en-48
5022-D057946
Revision: 02
8 Maintenance and disposal
8.1 Maintenance work
8.1.1 Maintenance
The drive amplifiers are maintenance free. Opening the drive amplifier voids the warranty.
8.1.2 Cleaning
Clean the drive amplifier IP65 with a grease-dissolving, non-aggressive detergent.
8.1.3 Visual inspection
Perform a
monthly
visual inspection:
Check the drive system and moving cables for damage.
Check whether the cable ends are completely labeled.
8.1.4 Repairs
The drive amplifier may only be repaired by the manufacturer. Opening the drive amplifiers
voids the warranty and safety according to the specified standards is no longer ensured.
8.2 Disposal
In accordance with WEEE 2002/96/EC directive, we take back old equipment for proper
disposal as long as the transport costs are paid by the sender.
9 Appendix
9.1 Tightening torques
Prope
rty
cl
as
s
Tightening torque [Nm] with thread
M
3
M
3.5
M
4
M
5
M
6
M
8
M
10
M
12
M
14
M
16
M
18
M
20
M
22
M
24
8.8 1.28 1.96 2.9 5.75 9.9
24
48
83
132 200 275 390 530
675
10.9 1.8 2.75 4.1
8.1
14
34
67
117 185 285 390 550 745
950
12.9 2.15 3.3 4.95 9.7 16.5
40
81
140 220 340 470 660 890 1140
Table 15: Tightening torques