EtherCAT:
Status
LED
Meaning
Off
The bus is ready for operation
Red
The bus is defective
Profinet:
Status
LED
Meaning
Off
There is communication with a Profinet
controller
Red
No connection available
Flashes
red
Connection available however there is no
active communication with an I/O
controller
EtherNet/IP:
Status
LED
Meaning
Off
There is communication with a
EtherNet/IP controller
Flashes
red
Connection timeout.
Previously active communication is
interrupted.
LED SERCOS III:
State LED
Meaning
off
The fieldbus is ready
glows red
Sercos communication error or
Sercos connection is not
established yet