Bedienungsanleitung Nr. 9999-041-0

Seite 1

B7202

_E_

1.pmd

12.06.2003

Electronic lock 7202

Fig. 1

Contents:

1.

Important notes

1.1

Explanation of terms

1.2

General

2.

Opening the electronic lock

3.

Closing the electronic lock

4.

Time-out following erroneous entries

5.

Correction with the „C“ button

6.

Battery charge monitoring, replacing the battery

7.

Emergency opening

8.

Programming the electronic lock

8.1

Programming the master combination

8.1.1

Programming a new primary combination using the
emergency opening lock

8.2

Programming a user combination

8.2.1

Deleting a user combination

8.3

Programming a timed delay period

8.3.1

Opening the lock with the timed delay function
activated

8.3.2

Deleting a timed delay period

8.4

Programming a time-lock period

8.4.1

Starting a time-lock period

8.5

Activating a combination interlock

8.5.1

Opening the lock with an interlock activated

8.5.2

Deleting an interlock

8.

Triggering a silent alarm

10.

Troubleshooting

1. Important notes

Please read these instructions carefully and
completely before putting the lock in operation.

Replace the  

0 _ 1 2 3 4 5 6

  factory combination

immediately by programming your own master
combination; see Section 8.1.

Do not use any personal data for your new master or
user combination.

The maximum permissible interval between any two
keypad entries is 30 seconds. If this limit is exceeded,
then the entire procedure will have to be repeated
from the beginning.

1.1 Explanation of terms

The following terms and symbols are used:

User number

   =

User number (abbreviated 

UNo

.)

UNo.

0

 for master

UNr.

1 to 5

 für users

Code

   =

A series of digits,
e.g.  4 7 6 2 3 9

Combination

   =

A series of digits required to open
the lock. It comprises the:

User number and code

:

Example for the master combination
0 _ 6 5 4 7 2 1
Example of a user combination
3 _ 8 7 9 5 8 3

Factory
combination  

   =

The initial combination, programmed at
the factory. The combination for this
electronic lock has been pre-set to

0 _ 1 2 3 4 5 6

Master
combionation   

=

Combination used by the master to
open the lock

User
combination   

  =

Combinations for additional users.
All user combinations are subordinate
to the master combination.

P - No.

   =

Program number

LED

   =

Light-emitting diode at the keypad.

Note

   =

Caution

   =

A signal tone sounds each time a button is pressed.

A 10-second time-out period will be started after
invalid combinations have been entered in three
consecutive attempts.

Do not damage the inspection seal on the lock as the
guarantee will otherwise be invalidated.

Summary of Contents for Insys 7202

Page 1: ...ing your own master combination see Section 8 1 Do not use any personal data for your new master or user combination The maximum permissible interval between any two keypad entries is 30 seconds If this limit is exceeded then the entire procedure will have to be repeated from the beginning 1 1 Explanation of terms The following terms and symbols are used User number User number abbreviated UNo UNo...

Page 2: ...ct the entry In this case you will have to repeat the entire entry sequence Correct entry is confirmed with a tone The green LED will now blink and the electronic lock is cleared for opening for a period of 12 seconds The door to the safe can now be unlocked using the keypad lever and the fingertip grip The green LED will blink at a 3 second interval for as long as the electronic lock is open The ...

Page 3: ...the 6 digit master or user combination e g Confirm the entry Enter the new 6 digit user combination e g Confirm the entry Enter the new 6 digit user combination again to confirm Confirm the entry Cancel A maximum of 5 user combinations can be programmed 9 8 7 6 5 4 The previous user combination will be retained if there is an error in programming UNo 1 UNo 5 Green LED blinks once OK green LED blin...

Page 4: ...1 minute release period Timed delay period of 11 to 59 minutes 2 minute release period 8 3 Programming a timed delay period Possible only with the electronic lock open and only with the master combination Initiate programming Select P No 3 Confirm the entry Enter 6 digit master combination e g Confirm the entry Enter timed delay period e g 1 minute Confirm the entry Cancel 1 minute to 59 minutes G...

Page 5: ...l blink every 30 seconds and the keypad will not respond to any entries at all Oncetheprogrammedtime lockperiodhaselapsedtheelectronic lock can be opened using either the master combination or a user combination The time lock period will run to completion once only after it has beenentered Theelectroniclockwillthenbereleasedforopening until such time as a new time lock period is programmed When th...

Page 6: ...nitiate programming Select P No 2 Confirm the entry Enter 6 digit master combination e g Confirm the entry Entry Confirm the entry Cancel 8 5 2 Deactivating the combination interlock function duality principle Possible only with the electronic lock open and only with the master combination Green LED blinks once OK green LED blinks once and low high tone sounds Error 12 high pitched tones and red L...

Page 7: ...ace the batteries or install them properly Keypad lever cannot be moved even though a valid combination has been entered correctly Batteries are too weak to release the electronic lock Replace the batteries Green LED blinks at 5 second intervals the electronics do not respond to any keypad entries A timed delay period has been inadvertently entered See notes at Sections 7 3 and 8 3 1 12 signal ton...

Reviews: