8.3.2 Deactivating a timed delay period

Possible only with the electronic lock open and only with the master combination.

Initiate programming
Select P - No. 3
Confirm the entry
Enter 6-digit master combination, e.g.
Confirm the entry
Entry
Confirm the entry

Cancel

Green LED blinks once

OK = green LED blinks once
and low-high tone sounds.
Error = 12 high-pitched
tones and red LED lights.

Function

Operation, button(s)

Response

Comments

8.4 Programming a time-lock period

Possible only with the electronic lock open and only with the master combination.

Initiate programming
Select P - No. 6
Confirm the entry
Enter 6-digit master combination, e.g.
Confirm the entry
Enter the time-lock period, e.g. °
Confirm the entry

Cancel

°

= 1 hour to
= 99 hours

Green LED blinks once

OK = green LED blinks once
and low-high tone sounds.
Error = 12 high-pitched
tones and red LED lights.

Function

Operation, button(s)

Response

Comments

8.4.1 Starting a time-lock period

The time-lock period will commence automatically, immediately
after it has been programmed. During the time-lock period the red
LED will blink every 30 seconds and the keypad will not respond
to any entries at all.
Once the programmed time-lock period has elapsed the electronic
lock can be opened using either the master combination or a
user combination.
The time-lock period will run to completion once only after it has
been entered. The electronic lock will then be released for opening
until such time as a new time-lock period is programmed.

When the interlock feature is active it will be necessary to enter 

two different combinations

, one after another, to open the

electronic lock. Any two combinations may be used. It is not possible for the master combination owner 

alone

 to open the lock

by entering the master combination twice; a second, user combination will have to be entered.

8.5 Activating a combination interlock (duality principle)

Possible only with the electronic lock open and only with the master combination.
At least two user combinations will have to have been programmed beforehand as otherwise an error signal will sound.

Initiate programming
Select P - No. 2
Confirm the entry
Enter 6-digit master combination, e.g.
Confirm the entry
Activate combination interlock
Confirm the entry

Cancel

Green LED blinks once

OK = green LED blinks once
and low-high tone sounds.

Error = 12 high-pitched
tones and red LED lights.

Function

Operation, button(s)

Response

Comments

Summary of Contents for Insys 7202

Page 1: ...ing your own master combination see Section 8 1 Do not use any personal data for your new master or user combination The maximum permissible interval between any two keypad entries is 30 seconds If this limit is exceeded then the entire procedure will have to be repeated from the beginning 1 1 Explanation of terms The following terms and symbols are used User number User number abbreviated UNo UNo...

Page 2: ...ct the entry In this case you will have to repeat the entire entry sequence Correct entry is confirmed with a tone The green LED will now blink and the electronic lock is cleared for opening for a period of 12 seconds The door to the safe can now be unlocked using the keypad lever and the fingertip grip The green LED will blink at a 3 second interval for as long as the electronic lock is open The ...

Page 3: ...the 6 digit master or user combination e g Confirm the entry Enter the new 6 digit user combination e g Confirm the entry Enter the new 6 digit user combination again to confirm Confirm the entry Cancel A maximum of 5 user combinations can be programmed 9 8 7 6 5 4 The previous user combination will be retained if there is an error in programming UNo 1 UNo 5 Green LED blinks once OK green LED blin...

Page 4: ...1 minute release period Timed delay period of 11 to 59 minutes 2 minute release period 8 3 Programming a timed delay period Possible only with the electronic lock open and only with the master combination Initiate programming Select P No 3 Confirm the entry Enter 6 digit master combination e g Confirm the entry Enter timed delay period e g 1 minute Confirm the entry Cancel 1 minute to 59 minutes G...

Page 5: ...l blink every 30 seconds and the keypad will not respond to any entries at all Oncetheprogrammedtime lockperiodhaselapsedtheelectronic lock can be opened using either the master combination or a user combination The time lock period will run to completion once only after it has beenentered Theelectroniclockwillthenbereleasedforopening until such time as a new time lock period is programmed When th...

Page 6: ...nitiate programming Select P No 2 Confirm the entry Enter 6 digit master combination e g Confirm the entry Entry Confirm the entry Cancel 8 5 2 Deactivating the combination interlock function duality principle Possible only with the electronic lock open and only with the master combination Green LED blinks once OK green LED blinks once and low high tone sounds Error 12 high pitched tones and red L...

Page 7: ...ace the batteries or install them properly Keypad lever cannot be moved even though a valid combination has been entered correctly Batteries are too weak to release the electronic lock Replace the batteries Green LED blinks at 5 second intervals the electronics do not respond to any keypad entries A timed delay period has been inadvertently entered See notes at Sections 7 3 and 8 3 1 12 signal ton...

Reviews: