background image

6

Primor 1000 / 3000 / 3010 / Level 5

5.2.1 Adjusting the time delay and opening window (programme 9)

1. Press and hold the key “9“ until the red LEDs lights up permanently.

9

2. Enter your 6-digit 

master code

 e.g.

123456

3. Enter the 

time delay 

e.g. 2 minutes.

02

4. Enter the 

opening window 

e.g. 10 minutes.

10

5. Re-enter the 

time delay 

e.g. 2 minutes.

02

6. Re-enter the 

opening window 

e.g. 10 minutes.

10

• The time delay can be increased at any time. It can be reduced only during the opening window.

5.2 Time delay and opening window

Only the master can program or delete the time delay.

Time delay:          01 - 99 minutes - time to wait until the lock can be opened.
Opening window: 01 - 19 minutes - within this time window the master or the user can open the lock with his code.

Code input – beginning of the time delay

Wait during the time delay

Opening window – re-enter code

Summary of Contents for Primor 1000 Level 5

Page 1: ...___________________3 4 2 Locking_______________________________________________________________3 4 3 Opening with key Primor 3010 emergency opening_______________________4 5 Programming the lock______...

Page 2: ...mes stay valid Every correct input while entering the code is confirmed by an acoustic signal and flashing of the red LEDs These signals will not be considered in this instruction The red LEDs flash d...

Page 3: ...mpanied by a long signal tone After the blocking time has passed 2 further incor rect inputs will restart the blocking time 4 2 Locking 1 Close the door at the safe and turn the handle into locking po...

Page 4: ...ing time The process will not be registered and cannot be read out by the PC software 1 Insert key so that the marking on the key head is pointing towards the lock s bolt 2 When using right hand locks...

Page 5: ...your new 6 digit code e g 567891 4 Re enter your new 6 digit code e g 567891 5 Programming the lock 5 1 Master and user code 5 1 1 Programming the user code programme 1 The master is able to program t...

Page 6: ...y e g 2 minutes 02 6 Re enter the opening window e g 10 minutes 10 The time delay can be increased at any time It can be reduced only during the opening window 5 2 Time delay and opening window Only t...

Page 7: ...lete the opening window 01 8 Delete the time delay again 00 9 Delete the opening window again 01 5 2 2 Opening with activated time delay and opening window 1 Enter your 6 digit code e g mastercode 123...

Page 8: ...atteries in an environmentally friendly way Fig 3 Input unit Primor FL battery compartement Fig 2 Input unit Primor RO FS To change batteries open the keypad Fig 1 Input unit Primor FE To change batte...