8
Primor 1000 / 3000 / 3010 / Level 5
7 Power supply and battery change
The lock is power supplied by one 9 V block battery alkaline (no rechargeable batteries!). When battery voltage is insufficient,
after entering the code a warning tone occurs repeatedly and the red LEDs flash alternately. Change the battery as quickly as
possible. The programmed codes stay valid during battery change.
Always dispose used batteries in an environmentally friendly way.
Fig. 3.: Input unit Primor FL/battery compartement
Fig. 2.: Input unit Primor RO/FS
To change batteries,
open the keypad
Fig. 1: Input unit Primor FE
To change batteries,
slide open the battery
compartement
6 Testing the system (programme 5)
Press every number once. A functional key will be confirmed by a double signal. A key that was not identi-
fied is confirmed by a long signal and the functional test is aborted. The system has to be checked.
1. Press and hold the key “5“ until the red LEDs lights up permanently.
5
2. Press every key in its order of appearance.
123
.......
90