Commissioning and operation
INTORQ | BA 14.0177 | 04/2016
22
6
Commissioning and operation
Important notes
6.1
Performing functional tests
Refer to
24 Troubleshooting and fault elimination for more information on the errors.
6.1.1
Release / voltage control
1. Remove two bridges from the motor terminals. Do not switch off the voltage supply to the brake.
2. Measure the AC voltage at the motor terminals. The measured level must be zero.
3. Switch on the current for the brake.
4. Measure the AC voltage at the motor terminals. It must be the same as the mains voltage.
5. Check the air gap "s
L
" between the brake disc and friction lining. It must be a total of 0.4 (± 0.1) mm. The
brake disc must be able to be turned freely.
6. Switch off the power supply.
7. Screw the bridges onto the motor terminals.
DANGER
Danger: rotating parts!
The brake must be free of residual torque. The motor must
not
be running!
DANGER
There is a risk of injury by electrical shock!
Live connections must
not
be touched.