Troubleshooting and fault elimination
INTORQ | BA 14.0177 | 04/2016
27
Brake disc cannot rotate
freely
Wrong setting of manual
release
❚
Check the dimension "s+s
L
" with the brake energized.
The dimension must be the same on both sides. Correct
if required.
Air gap "s
L
" is too small
❚
Check air gap "s
L
" and replace brake if necessary.
(
❚
Check the thickness of the brake disc and replace the
brake disc if necessary.
❚
Check the movability of the brake on the guide sleeves
and, if necessary, replace the guide sleeves.
Voltage not zero during
functional test
Incorrect microswitch wiring
Check and correct the wiring of the microswitch.
Microswitch defective or
incorrectly set
Replace the brake and send the defective brake to the
manufacturer.
Voltage too high
Brake voltage does not match
the rectifier
Adjust rectifier and brake voltage to each other.
Voltage too low
Brake voltage does not match
the rectifier
Adjust rectifier and brake voltage to each other.
Defective rectifier diode
Replace defective rectifier with a suitable undamaged one.
AC voltage is not mains
voltage
Fuse is missing or defective
Select a connection with proper fusing.
Incorrect microswitch wiring
Check and correct the wiring of the microswitch.
Microswitch defective or
incorrectly set
Replace the brake and send the defective brake to the
manufacturer.
Fault
Cause
Remedy