14
www
.wittur
.com
Changes can be made without notice
PM.2.004923.EN - 811-000-000 SDS
©
DC-PWM Compatible · Edition 22 July 2020
Drive - Instruction Manual
OUTGOING SIGNALS FROM THE DOOR CONTROLLER
Signal
Connector Pins
Contact type & Normal state
Notes
Opening limit switch contact La
Connector pins
16-17
These connections provide dry
(voltage free) contact.
The contact is open when the door
is fully open.
Contact rating: 3A 250Vac 30Vdc
Closing limit switch contact Lc
Connector pins
18-19
These connections provide dry
(voltage free) contact.
The contact is open when the door
is fully closed.
Contact rating: 3A 250Vac 30Vdc
Reversing system signal IM
Connector pins
1-4
These connections provide dry
(voltage free) contact.
(contact normally closed)
This signal is generated by dry
(voltage free) Form C contacts
(relay within the Door Controller)
and is activated only when either
a mechanical obstacle (excessive
force) prevents the doors from
closing, or a signal is received from
an external safety device that is
connected to the door controller.
It is used to signal the main lift
controller to interrupt the door
close command and give a door
open signal. Contact rating: 3A
250Vac 30Vdc
Connector pins
2-4
(contact normally open)
Auxliary autput signal AUX
Connector pins
34-35
These connections provide dry
(voltage free) contact.
(contact normally open
These contacts can be used to
signal that a particular (pre-set)
door opening distance has been
achieved, or as a Gong or Buzzer
while the door is opening or as a
Thermic alarm signal.
Contact rating: 3A 250Vac 30Vdc.
Connector pins
35-36
(contact normally closed)
Motor
Connector pins
43-44-45
Factory-prewired connector
Acoustic alarm (BUZZER) Optional
Connector pins
15-21
These connections provide a 24Vdc,
100ma contact. Contact is open
when not active.
•
For the Door Operator mechanical installation refer to the “Installation and maintenance of Sematic doors” manual.
•
Warning: to avoid possible induced currents within field wiring, it is recommended to shield the Ka and Kc signals (connector pins
3, 5 and 15) with grounded, shielded cables.
•
Changes made to the factory wiring length or position can damage the EMC system characteristics and is not recommended.
4.3 DETECTOR/PHOTOCELL/BARRIERS: SIGNAL-ONLY CONNECTION TO THE DOOR CONTROLLER (DIRECT
CONNECTION)
This connection requires a dry (voltage free) external relay contact connected to the Door Controller Connector pins 15 & 23.
If desired, it is possible to connect the single output signal from a photocell (or similar device) formed by a voltage free contact, so that the
door controller will directly receive the command to re-open.
The photocell (or similar device) has therefore an independent power supply and sends only its outgoing signal to the Sematic Drive
System
©
controller.
Reopening is operated according to the REVERSING SYSTEM, LIMITED DOOR REVERSAL EFFECT and PROTECTIVE DEVICE LOGIC
settings (see sections
“6.2 Reversing System choice: INTERNAL or EXTERNAL” a pag. 19
“6.3 Limited Door Reversal” a pag. 19
and