4.5 MAGNETIC SWITCHES
Verify that the magnet (1) has the countersink for the self-threading screw on the side of the magnetic switch (2).
Open and close the door by means of the controller or manually and make sure that the magnetic switches work correctly.
For K1-2-3R
For K1-2-3L and K2-4-6
These are the operations of the magnetic switches:
•
Closed door
- the door close limit (pre-adjusted by the manufacturer) must operate when the carriage has already stopped but the
retractable skate is not closed;
•
Open door
- the door open limit (pre-adjusted by the manufacturer) must operate approx 5 mm before the door is totally open; (note:
not used for DIGIDOOR operator compatibility);
•
The
closing slow down limit
causes the doors to slow down before they are totally closed;
•
The
opening slow down limit
causes the doors to slow down before they are totally open.
Attention: