17
www
.wittur
.com
Changes can be made without notice
PM.2.004923.EN - 811-000-000 SDS
©
DC-PWM Compatible · Edition 22 July 2020
Drive - Instruction Manual
5 INSTRUCTION WITHOUT HANDSET
Display in Automatic and Manual Mode
5.1 AUTOMATIC MODE “AUTO”
•
When the Door Controller is working in automatic mode the “AUTO” red led is on, whereas the other two red leds are off.
•
When the Door Controller is switched on, or after a self-resetting, it starts directly in the automatic mode.
•
All the signals sent by the main lift controller and by the external devices (barriers, photocells, etc.) are active in this mode.
•
Keys 2 and 3 are not functional during automatic mode.
•
When Key 4 is kept pressed for a while, the Door Controller (ca. 3 sec.), switches to the manual mode “MAN”.
5.2 MANUAL MODE “MAN”
•
When the Door Controller is working in manual mode the “MAN” red led is on, whereas the other two red leds are off.
•
All signals coming from the main lift controller and from other external devices are ignored.
•
The IM contact is deactivated, therefore the Door Controller does not recognize any signal coming from the external devices to
reverse door movement, such as photocells or barriers.
•
Opening and Closing commands may be manually input by pushing Key 2 (open) or Key 3 (close).
•
When key 4 is kept pressed for a while (Appx. 3 sec.), the Door Controller switches to the automatic mode “AUTO”.
•
If no keys are pressed for at least 10 minutes, the Door Controller will switch to the “automatic mode “AUTO”.
Both in automatic and manual mode the Door Controller will show the following display:
Door opening (Flashing Display)
Door open
Door closing (Flashing Display)
Door closed
Forced closing
It signals an alarm and flashes giving the code of the
recognised alarm. See
“10 Controller software upgrade” a pag.
Reversing system on
5.3 PROGRAMMING MODE “PROG”
•
When the Door Controller is working in “programming mode” the “PROG” red led is on whereas the other two red leds are off.
•
Press contemporaneously Key 1 and Key 4 for few seconds to enter the programming mode. The display on the Door Controller will
show “P” and “00” flashing alternately.
•
When the Door Controller is in the programming mode, all signals coming from the main lift controller and from the external
devices (barriers, photocells,…) are ignored.
•
The parameter to be modified is selected by means of the increasing and decreasing KEYs, respectively the buttons 2 and 3; this
parameter is then confirmed by pushing the key 1, ENTER.
•
After confirming the parameter to be modified, the display shows the relevant numeric value.
•
Modify the chosen parameter using the key 2, increase, and 3, decrease, and confirm the changes by pressing key 1 ENTER.
•
At the end of the necessary configurations, using the key 4 press to select the required operating mode (manual “MAN” or automatic
“AUTO”).