PM.2.004923.EN - 811-000-000 SDS
©
DC-PWM Compatible · Edition 22 July 2020
Drive - Instruction Manual
is closed in normal conditions and it opens to signal the presence of an obstacle.
WARNING
: if the selected logic is Kn N/C on obstruction open (contact opens to signal the presence of an obstacle) and is used
only one protective device input (
15-23
) terminals for photocells,
30-31-32-33
terminals for direct connection of protective
barriers), the other input must be shorted. For example if N/C logic protective barriers are connected to
31-32-33
terminals,
23
and
15
terminals must be shorted; if N/C logic photocells are connected to
23
and
15
terminals,
31
and
32
terminal must be shorted.
6.10 EMULATION TYPE
SDS DC-COMPATIBLE controller may replace different kind of old controllers. Usig this parameter is possible to select requested controller
emulation type within the following list:
•
Emulation F28
•
Emulation F29
•
Emulation DIGIDOOR 1Nm
•
Emulation DIGIDOOR 2Nm
•
Emulation LM-DC 2010
•
Emulation LM-DC 2011
It’s possible to select the emulation type with the SDS Handset (
“8.10 Emulation Type” a pag. 28
) or in programming mode “PROG” (
Programming Mode “PROG”” a pag. 17
Note
: if Digidoor controller compatibility is requested please verify the Main Lift Controller signals logic and voltage rate.
If these values don’t fit with the range and the logic explained in
“4 Signals to/from the door controller” a pag. 11
, it is possible to install the Sematic Interface
Kit cod. B066AAPX following the enclosed instruction.