8 GENERAL OPTION
•
Connect the handset to RJ45 connector;
•
If necessary, using keys
ã
and
ä
choose the required language and confirm with the “OK” key
•
Using keys
ã
and
ä
run through the MAIN MENU and choose GENERAL OPTIONS
•
Press OK to confirm the choice
•
The GENERAL OPTION menu allows the Door Controller to operate by means of the following parameter options:
−
REVERSING SYSTEM
−
MAIN LIFT CONTROLLER TEST
−
NO MLC SIGNAL
−
MLC INPUT ALARM
−
LIMITED DOOR REVERSAL
−
CAR DOOR LOCKING DEVICE
−
GLAZED PANELED DOORS
−
AUX OUTPUT RELAY
−
PROTECTIVE DEVICE LOGIC
−
EMULATION TYPE
These parameter meanings and settings are detailed in the following paragraphs.
8.1 REVERSING SYSTEM SETTING BY MEANS OF THE HANDSET
•
“6.1 Reversing system force setting” a pag. 19
for the meaning of this parameter
•
Using keys
ã
and
ä
run through the GENERAL OPTIONS and choose the option REVERSING SYSTEM
•
Press the “OK” key to confirm the choice
•
The following options are viewed on the display:
−
INTERNAL
−
EXTERNAL
•
Using keys
ã
and
ä
choose the required option and press the “OK” key to confirm it
•
The display shows the confirmed option and restores the menu GENERAL OPTIONS
•
The following options are available:
−
“BACK”: Press key F1 to restore the menu GENERAL OPTIONS
−
“MENU”: Press key F3 to restore the MAIN MENU
8.2 ACTIVATION OF THE MAIN LIFT CONTROLLER TEST BY MEANS OF THE HANDSET
•
“6.4 Main Lift Controller Test” a pag. 19
for the meaning of this parameter
•
Using keys
ã
and
ä
run through the GENERAL OPTIONS and choose the option MAIN LIFT CONTROLLER TEST
•
Press the “OK” key to confirm the choice
•
The following options are viewed on the display:
−
WHEN MOVING
•
The display shows the confirmed option and restores the menu GENERAL OPTIONS
•
The following options are available:
−
“BACK”: Press key F1 to restore the menu GENERAL OPTIONS
−
“MENU”: Press key F3 to restore the MAIN MENU
8.3 ACTIVATION OF THE MAIN LIFT FAILURE BY MEANS OF THE HANDSET
•
“6.4.1 No MLC Signal” a pag. 19
for the meaning of this parameter
•
Using keys
ã
and
ä
run through the GENERAL OPTIONS and choose the option NO MLC SIGNAL
•
Press the “OK” key to confirm the choice
•
The following options are viewed on the display:
−
IMMEDIATELY STOP
•
The display shows the confirmed option and restores the menu GENERAL OPTIONS
•
The following options are available:
−
“BACK”: Press key F1 to restore the menu GENERAL OPTIONS
−
“MENU”: Press key F3 to restore the MAIN MENU
8.4 MAIN LIFT CONTROLLER ALARM - (MLC INPUT ALARM)
•
“6.4.2 Main Lift Controller Input Alarm” a pag. 19
for the meaning of this parameter
•
Using keys
ã
and
ä
, run through the GENERAL OPTIONS and choose the option MLC INPUT ALARM
•
Press key “OK” to confirm the choice
•
The following options are viewed on the display:
−
OFF
−
ON
•
Using keys
ã
and
ä
, choose the required option and press the “OK” key to confirm it
•
The display shows the confirmed option and restores the menu GENERAL OPTIONS
•
The following options are available:
−
“BACK”: Press key F1 to restore the menu GENERAL OPTIONS
−
“MENU”: Press key F3 to restore the MAIN MENU
8.5 LIMITED DOOR REVERSAL ACTIVATION BY MEANS OF THE HANDSET
•
“6.3 Limited Door Reversal” a pag. 19