39
www
.wittur
.com
Changes can be made without notice
PM.2.004923.EN - 811-000-000 SDS
©
DC-PWM Compatible · Edition 22 July 2020
Drive - Instruction Manual
16 UPGRADE FROM DIGIDOOR CONTROLLER
•
Eliminate the transformer 220/24 V with all its cables because the new SDS is fitted with an in-built switching transformer
•
Disconnect all the connectors to be substituted on the controller and connect them again to the new controller using the
connectors-adatpers Code nr. B066AAPX; this way no wiring operation is necessary and the substitution is quick and easy.
IMPORTANT
: Please check the signal logic and the voltage range of the in-coming signals from the control board. In case all the
parameters do not correspond to the range and logics given in chapter 4, it is possible to instal the Sematic interface kit code no.
B066AAPX and follow the instructions enclosed to it and in chapter 7.
•
If the connectors-adapters Code nr. B066AAPX are not available: disconnect the wires from the old connectors and connect them
again following the correspondence given in the underneath table
•
Connect the 220 Vac input to the SDS controller by means of the feeding cable supplied code no. E066AAWX-A
•
Select option EMULATION DIGIDOOR 1Nm or EMULATION DIGIDOOR 2Nm from the Menu General Option (see
) or programm parameter 22 using the keys on the frontal panel (03 o 04, see also
).
•
Check the correct functioning
TERMINALS
FUNCTION
SEMATIC SDS Rel. 3
DC COMPATIBILE
1
IM reversing system N/C signal
1
2
IM reversing system N/O signal
2
3
Closing control Kc
3
4
IM reversing system COM signal
4
5
Ka opening control
5
6
COM 24 Vdc
15
7
24 Vac power
NOT CONNECTED
8
24 Vac power
NOT CONNECTED
9
Motor power
43
10
Motor power
44
11
Ra opening slow down Input signal
41
12
NOT CONNECTED
13
Rc closing slow down Input signal
42
14
NOT CONNECTED
15
COM 24 Vdc
15
20
Forced closing (nudging) Input control
22
21
15
22
23
24
Lc Closing limit switch input contact (from the magnetic switch)
39
25
La Opening limit switch output contact (to the main lift controller)
16
26
La Opening limit switch output contact (to the main lift controller)
17
27
Lc Closing limit switch output contact (to the main lift controller)
18
28
Lc Closing limit switch output contact (to the main lift controller)
19