6.3. Relubrication of the bearings
Relubricate the main bearing after about 7,000 hours of operation or every 3 years, using a KP 2 N-30 to DIN 51
502 grease such as Wälalit LZ 2 or Klüberlub BE 41-542 (approx. 205 g on DE and approx. 55 g on NDE).
Use a conventional grease gun and press the grease into the hydraulic-type grease nipples to DIN 71 412
AM 10x1.
The relubricating points are provided on the D- and N- end shields of the machine. The DE grease nipple is
located behind the traction sheave.