7.
Type code
Example:
W
S
G- 29 .
2
-
0
0
1 7
/
6 5 A
-
D F
W
S
G- 29 . Z3 -
X1
X2
X3 X4
/
X5 X6 X7
-
X8 X9
Customer specific
identifier
S = Synchronous motor
G = Synchronous motor,
split housing design
G = gearless
U = gearless; UL-CSA approved
Frame size
Z3: Overall length:
3 overall lengths are available;
identified by: 1, 2, 3
X1: Customer specific identifier
X2: Motor voltage:
0: suitable for inverter supply using a link voltage of 500 …. 620 V DC
X3 X4: Rated speed:
e.g. 11: 118 min
-1
(with D
T
= 650 mm v = 2.0 m/s; suspension 2:1)
17: 176 min
-1
(with D
T
= 650 mm v = 3.0 m/s; suspension 2:1)
29: 294 min
-1
(with D
T
= 650 mm v = 5.0 m/s; suspension 2:1)
X5 X6 X7: Traction sheave design
(Traction sheave diameter; width, groove design, groove geometry)
X8 X9: Variant code (brake, measuring system, modifications)
ZE: 3 clasp brakes; measuring system ECN 1313-2048 incr. - SSI-interface
ZF: 3 clasp brakes; measuring system ECN 1313-2048 incr. - ENDAT-interface
ZG: 3 clasp brakes; measuring system ERN 1387-2048 incr.
2E: 2 clasp brakes; measuring system ECN 1313-2048 incr. - SSI-interface
2F: 2 clasp brakes; measuring system ECN 1313-2048 incr. - ENDAT-interface