Subject to changes without notice !
Änderungen vorbehalten !
Gearless Lift Machine
WSG-25
Operating Instructions
EN
Code: GM.8.002673.EN
Date:
07. May 2019
Version: 0.13a
Page: 24
Extraction of the grease
With the re-lubrication the old or surplus grease is pressed in a collector duct. The collector duct is big enough to catch
grease of 12…15 proper re-lubrications and is therefore sufficient for the lifetime of the machine.
If necessary, the collector duct can be opened with a grub screw on D-end and ND-end.
Grub screw
DIN 916-M 20 x 25
Grub screw
DIN 916-M 10 x 12
DE extraction of the grease
NDE extraction of the grease
8.4. Fan filter mats
Remove the three screws from the protective screen. Then remove the screen and filter to clean or replace the filter
mats.
WARNING
f
Do this work only with the fan switched off as the rotating fan wheel could be dangerous.
f
Operation of the motor without fan filter mats is not permitted!