Commissioning and operation
INTORQ | BA 14.0210 | 12/2016
38
6.2.2
Testing the manual release functionality
Fig. 16
Turning direction of the lever
Motor and brake are de-energized.
14. Suspend Bowden cable (not included in the delivery package) and pull with approx. 800 N.
-
The drive must be able to be turned freely. A low residual torque is permitted.
15. Release the lever.
-
Torque must be available!
The preparations for commissioning are completed.
6.3
Commissioning
1. Switch on drive system.
2. Carry out a braking test.
NOTICE
❚
The manual release is designed for activation via a Bowden cable.
❚
An individual brake circuit can only be released electrically.
DANGER
Danger: rotating parts!
The drive system must be free of loads. The motor must not run!