Gearless Lift Machine
WSG-TB
Operating Instructions
Subject to changes without notice ! Subject to changes without notice !
EN
Qualified personnel
Only qualified personnel are authorised to perform any planning, installation or maintenance work, and this
must be done in accordance with the relevant instructions. The personnel must be trained for the job and must
be familiar with the installation, assembly, commissioning and operation of the product.
2.2. Format of the safety instructions
The safety instructions contained in this operating manual are presented in a standardised format.
They comprise a
danger signal word + instruction text
. The danger symbol indicates the type of dan -
ger, the signal word specifies the severity of the danger, and the instruction text describes the danger and
explains how to avoid it.
Danger symbols
Signal words
•
Danger
Serious injuries or death will result
•
Warning
Serious injuries or death may result.
•
Caution
Minor to moderate injuries may result.
•
Notice
Property damage may result.
•
Information
Points out useful information.
2.3. Safety precautions
• Check the proper functioning of the motor and the brake after installing the machine.
• Repairs may only be carried out by the manufacturer or an authorised repair agency. Unauthorised opening
and tampering may result in injuries to persons and property.
• The machines are not designed for direct connection to the three-phase system but are to be operated via an
electronic frequency inverter. Direct connection to the mains may damage the motor beyond repair.
• High surface temperatures may occur on the external parts of the machine. Therefore, no temperature-sensi -
tive parts may be in contact with these parts or attached to them. Protection against accidental contact
should be provided, if required.
• The EU type-examined fail-safe brakes provided are designed only for a limited number of emergency brak-
ing operations. They must not be used as working brakes.
• If the motor is not energised, no torque is produced. This may result in uncontrolled acceleration of the lift,
if the brakes are released. Therefore, the motor winding should be short-circuited to produce a speed-depen -
dent braking torque while the motor is not supplied with current. (Use the main contacts for short-circuiting
as rated motor current may be flowing.) The motor must never be short-circuited while it is energised.
• High voltages are present at the terminal connections during the operation of synchronous motors.
Risk of electric shock
Property damage
General danger
Information
Gearless Lift Machine
WSG-TB
Operating Instructions
Code
GM.8.004610.FR
Date
14.05.2018
Statut
0.01
Page
5
Subject to changes without notice ! Subject to changes without notice !
EN
Summary of Contents for WSG-TB.3 series
Page 29: ......
Page 30: ......
Page 31: ......
Page 33: ......
Page 37: ......
Page 38: ......
Page 39: ......
Page 43: ......
Page 44: ......
Page 45: ......
Page 46: ......
Page 47: ......
Page 95: ...Notes INTORQ BA 14 0197 04 2016 48 Notes...
Page 144: ...Notes INTORQ BA 14 0210 12 2016 48 Notes...
Page 145: ...Notes INTORQ BA 14 0210 12 2016 49...
Page 146: ...Notes INTORQ BA 14 0210 12 2016 50...
Page 147: ......