Mechanical installation
INTORQ | BA 14.0197 | 04/2016
30
4. Screw self-locking nuts (12.8) onto the stud bolts and tighten them until the dimension "s" has been set.
Abb. 13
Dimension "s"
NOTICE
Before setting the dimension "s", it is imperative that the air gap "s
L
" is checked, and adjusted
to "s
LN
" (
16), if required. The brake is
not
energised during adjustment.
1.1 Stator, complete
6
Flange
12.1 Lever
2
Armature plate
Type
s
LN
+0.05
[mm]
s
+0.1
[mm]
BFK464-17
S
0.4
5.3
BFK464-18
S
BFK464-18
S.2
BFK464-19
S
BFK464-20
S
BFK464-20
S.1
BFK464-22
S
6.5
BFK464-25
S
5.3
BFK464-25
S.1
BFK464-28
S
0.5
6.5
DANGER
Brake may fail
If the manual release is not adjusted correctly the brake may fail.
Possible consequences:
❚
Severe injuries or material damage.
Protective measure:
❚
Ensure that the dimension "s" is observed.