4. Scope of supply
Gearless Lift Machine
WSG-W8
Operating Instructions
•
Lift machine WSG-W8 according to order specification
•
Operating instructions
•
Screws for disassembly the brake
•
Delivery note
Options:
•
Release lever set with remotely controlled bowden
cable
•
Connecting cable for measuring system
•
Cable set for motor and brake
•
Manual turning device
•
Rubber isolation pads
Seite/page
9
Datum/date
29.01.2010
Stand/version
0.13
5. Transport and storage
The lift machines leave the factory in perfect condition
after being tested.
Make a visual check for any external damage immediate-
ly upon their arrival on site. If any damage incurred in
transit is found, make a notice of claim in the presence
of the carrier. If necessary, do not put these machines
into operation.
Transport
Observe the relevant safety regulations and
take the centre of gravity into account
when handling the lift machines.
The eyebolts are designed for the specified machine
weight, i.e. additional loads must not be applied.
Storage
Store the motors only in closed, dry, dust-free, well-ven-
tilated and vibration-free rooms (storage temperature:
-20°C to 60°C). Do not store lift machines in the open air.
Bright parts are not sufficiently preserved to withstand
extended periods of exposure.
Avoid excessive storage periods (recommendation: max.
one year).
After prolonged storage (>3 months), rotate the motor in
both directions at a low speed (< 20 min
-1
) to allow the
grease to distribute evenly in the bearings.
Measure the insulation resistance before initial operation
of the machine. If the value has dropped below < 1 kW
per volt of rated voltage, the winding needs to be dried
(insulation meter voltage: 1,000 V DC). This can be done,
for instance, with heated air, in a drying oven, or by
applying a d.c. voltage to the motor connections.
Unpacking
Dispose of the packaging material in an
environmentally friendly manner or reuse
it.
Any special transport aids or shipping
braces are left with the customer.
Warning
Note
Änderungen vorbehalten!
Subject to changes without notice!
Make sure that the voltage selected does not exceed the
values shown in the figure
"Drying the winding".
Let the temperature rise to about 70 – 80°C and maintain
it for several hours.
u
v
w
A
I
≈
45% I
N
-
U
Drying the winding