background image

 

 

WT-2009 IP65 GSM-AUTO 

WT-2009 IP65 GSM-AUTO – USER MANUAL – Rev. 1.0  

You will receive the following confirmation from the unit #ACM-ON confirming the security access mode is 
on 
 
To turn off the security access mode you would send the following SMS text message to the unit 
#PWD121212#ACM0 
 
You will receive the following confirmation from the unit #ACM_OFF confirming the security access mode 
is switched off and open access mode is activated 
 
#TEL 
Administrator List 
This is the command that allows you to add or remove the administrator numbers that will receive alert 
messages from the unit when the relays are switched on via SMS text message. 
 
It is possible to add up to 8 Administrator numbers to the list and it is possible to use up to 16 digits in 
the numbers. 
 
These SMS confirmation text messages only apply to the following commands #RLY and #RLOP 
 
To add 07827829595 to the administrator list you would send the following SMS text message to the unit 
#PWD121212#TEL1=07827829595 
 
You will receive the following confirmation from the unit #TEL1:07827829595 
 
To check all the administrator number in the list you would send the following SMS text message to the 
unit. #PWD121212#TEL? 
 
You will receive the following similar confirmation from the unit 
 
#TEL1:07827829595 
#TEL2:07452314592 
#TEL3:07865923401 
 
#RERN 
This is the command that allows you to enable, disable and check the status of the administrator list, 
these are the numbers that will receive text alerts. 
 
To allow the first 4 administrators in the Administrator List to receive text alerts only, you would send the 
following SMS text command to the unit. #PWD121212#RERN=11110000 
 
Where 1 is a number enabled for the first 4 positions in the administrator list and 0 is a number disabled 
for the last 4 positions in the list. 
 
You will receive the following confirmation from the unit #RERN=11110000 and the first four 
administrator numbers in the list will receive SMS text alerts 
 
To check the status of the RERN list you would send the following SMS text message to the unit 
#PWD121212#RER? 
 
You will receive the following similar confirmation from the unit #RERN=11110000 
 

Summary of Contents for WT-2009

Page 1: ...at connects to the GSM cell phone network It is activated by calling its cell phone number it will reject the call without answering and switch on the device connected to it There are no call charges...

Page 2: ...to access the SIM card carrier gently push the button adjacent to it insert the SIM card and carefully close the carrier connect the antenna Connect a 12 volt DC power supply to terminal 1 2 ensuring...

Page 3: ...mum current of 1 Amp 3 COMMON COM 4 NORMALLY CLOSED N C 5 NORMALLY OPEN N O RELAY 2 6 NORMALLY CLOSED N C 7 NORMALLY OPEN N O 8 COMMON COM RELAY 1 Example Connections HEATER 110V ac LIGHT 110V ac 1 2...

Page 4: ...paces or any other characters Programming Commands If you are familiar with the commands a quick reference can be found on page 10 PWD Password This command must always pre fix any SMS text commands t...

Page 5: ...r PWD121212 WHL01 27829595 You will receive the following confirmation from the unit WHL01_OK This is the first number in the White list and number 2 is sent as WHL02 and so on up to a maximum of 99 n...

Page 6: ...212 TEL1 07827829595 You will receive the following confirmation from the unit TEL1 07827829595 To check all the administrator number in the list you would send the following SMS text message to the u...

Page 7: ...00900 Where 1 indicates relay number 1 and 00900 is the relay on time in seconds this should be entered in 5 digits format as shown You will receive the following similar confirmation from the unit GO...

Page 8: ...is the on time in seconds this should be entered in 5 digits format as shown You will receive the following confirmation from the unit RLY2 ON 00360 when relay 2 switches on and the following confirma...

Page 9: ...lowing confirmation from the unit SMW 00 00 21 01800 1 1 To program the output relay 2 to turn on for 1 hour at 6am you would send the following SMS text message to the unit PWD123456 SMW 00 00 06 036...

Page 10: ...rity Access Mode ACM ACM2 ACM0 On Off Administrator List TEL TEL1 827829595 Position telephone number Up to 16 digits Up to 8 numbers Check signal strength CSQ CSQ 0 31 minimum 5 required Relay ON tim...