Original operation manual
AIRCOMBI
15
AirCombi_BAoDB_en_1701 • rs
Safety
WARNING
If the maximum permissible air inlet pressure is exceeded, components
may burst. This may result in damage to persons and property.
➤
Never allow the machine to run without a safety valve or with a defec-
tive one!
➤
If the safety valve needs to be replaced, you can find the corresponding
order number on the machine card.
➤
With new safety valves, ensure that they have been set to the maximum
permissible air inlet pressure of the machine (see type plate / machine
card) and sealed with a lead seal.
2.4.2 Compressed air shut-off valve
The compressed air shut-off valve enables immediate shutting down of the
machine.
Das Funktionsprinzip:
Open
set in the direction of flow
Close
set across the direction of flow
Fig. 3
: Compressed air shut-off valve OPEN
Fig. 4
: Compressed air shut-off valve CLOSE
After shutting off the air, the machine is still pressurized. This means that
before carrying out maintenance and repair work, you must always carry
out a complete pressure release!
2.4.3 Ground cable
The ground cable prevents the
electrostatic charge of the machine.
The ground cable is already connected
to the machine when it is delivered (e.g.
on the high pressure filter, the ground
bar, etc.).
Replace the ground cable immediately if
it lost or damaged!
Fig. 5
: Ground cable