32
Original operation manual
AirlessPhoenixGX_BA_en_1803 • 0550010-en • jw
Transport, installation, and assembly
Observe and adhere to the separate operation manual for the
spray gun.
4.3.2 Grounding the machine
WARNING
The high flow velocities during the airless spray process can
result in an electrostatic charge. Static discharges can result in
fire and explosions.
➤
Ensure that the machine is properly grounded outside
of EX zones!
➤
Also ground the object that is to be coated.
1.
Connect the machine’s ground cable to an electrically
conductive object outside of EX zones.
2.
Ensure correct grounding of the object to be coated.
4.3.3 Connecting the compressed air
To ensure the required quantity of air, the compressor output
must comply with the air requirement of the machine, and the
diameter of the air supply hoses must match the connections.
Operation with contaminated or moist compressed air leads to
damage in the machine’s pneumatic system.
➤
Use only dried, oil-free and dust-free compressed air, which
corresponds to compressed air quality grade 4 according to
DIN ISO 8573-1!
1.
Ensure that
•
the compressed air
shut-off valve is closed,
•
the compressed air
regulator is completely
throttled back.
2.
Insert compressed air line
(coupling DN 7.2, G¼“A)
Fig. 13
: Connecting the compressed air