Maintenance
6.4.2 Filter elements for the high pressure filter
Insert a filter element in the high pressure filter that is appropriate
for the spray product and fits the spray nozzle. The mesh size
should always be somewhat finer than the hole in the nozzle used:
Filter element Nozzle size
WIWA
order number
M 200 (white)
up to 0,23 mm/.009“
0659107-200
M 150 (red)
> 0,23 mm/.009“
up to 0,33 mm/.013“
0659107-150
M 100 (black)
> 0,33 mm/.013“
up to 0,38 mm/.015“ 0659107-100
M 70 (yellow)
> 0,38 mm/.015“
up to 0,66 mm/.026“
0659107-070
M 50 (orange)
> 0,66 mm/.026“
0659107-050
M 30 (blue)
0659107-030
M 20 (green)
0659107-020
Do not use a filter element with coarse pigmented or fiber-filled
materials. The suction screen installed as standard should
remain in the screen housing or be replaced with a coarse-
meshed screen. In the event of a material change, the filter
element of the high pressure filter and the material screen of the
suction system must be cleaned or replaced if necessary.
6.5 Recommended operating fluids
Only use original operating fluids from
WIWA
:
Operating fluid
WIWA order number
Release agent, yellow (0,5 l) ¹
(used by default)
0163333
Release agent, red (0,5 l) ¹
(e.g. for isocyanate in the PU area)
0640651
¹
Plasticizer for filling the release agent vessel of the high pressure
pump.
The release agents are also available in larger containers upon
request.