4
Assembly and Setting up
24
Translation of the original operation manual
•303_208176_1004_en•ski
Check maximum pressure
Please check the permissible maximum pressure for the material hose and spray gun*.
It must be greater than or equal to the maximum operational pressure for the system,
which is shown on the type plate on the high pressure pump or on the machine card.
Compare the maximum operating pressure of the safety valve with the information on the
machine card or the type plate. This information must correspond.
Adding release agent
Add release agent in the three release agent chambers of the DUOMIX (picture 4.1). We
recommend using
- release agent (for order no. see the chapter “appendix”).
Adding pneumatic oil
Fill pneumatic oil into the oiler of the air maintenance unit and adjust it.
In very cold working conditions you may add some anti-freeze to avoid icing.
Drop metering of Fog Oiler (picture 4.2)
Let the equipment run slowly and check that with every 10 - 15 cycles, one drop of pneu-
matic oil is fed from the oiler into the air motor.
If the droplet metering differs, use a screw driver to set the regulating screw accordingly.
For optimal protection we recommend the use of
- pneumatic oil and the
- antifreeze (for order no. see the chapter “appendix”).
Connecting equipment provided by the operator
When there is equipment not included in the delivery, but which is necessary for the
proper use of the unit, it is the responsibility of the
operator
to install this equipment
before the initial start-up.
Equipment to be installed:
➤
Spray gun*
This equipment is also listed in the description of the operational procedures and marked
with an asterisk (*) .
Picture 4.3
Picture 4.4