•303_208176_1004_en•ski
➤
Open the shut-off ball valves (pos. 10.2) on the material pump feed lines.
➤
Remove the return hoses (pos. 9) from the filling container and secure them in a
separate open container.
➤
Now, turn switch MANUAL/AUTOMATIC (pos. 1.3) on control panel to “MANUAL”.
CAUTION!
In the “MANUAL” position, monitoring of pressures
below
the adjusted spraying pres-
sure is not activated. For safety reasons, monitoring of pressures
above
the adjusted
spraying pressure is in effect. Monitoring is achieved via the pressure gauges of compo-
nents Base and Hardener.
The air regulator with finest filter (pos. 1.4) is factory-set at 6 bar, the precision air regulator
(pos.1.5 ) in the control panel is factory-set at 1.4 bar.
Do not change these settings!!
Settings on the mixer (Circulate)
➤
Turn lever on the external mixer:
➤
SPRAY (pos. 13.2) to “CLOSED”.
➤
FLUSH (pos. A / B) to “CLOSED”.
➤
CIRCULATE (pos. 13.1) to “OPEN”.
➤
Make sure that the air regulator (pos. 2.2) on the main pump is set to 0 bar, to insure
that the unit can start from a complete stop.
➤
Open the shut-off (pos. 2.1) ball valve on the maintenance unit and release the STOP
button (pos. 1.2) (unlock it by pulling it out).
unlock it by pulling it out)..
➤
Press the START button (pos. 1.1) and set the air regulator on the main pump to 0,5 - 1
bar by turning to the right.
Testing of the proper function of the STOP button
➤
Before the first use of the unit you should check the proper function of the STOP but-
ton (pos. 1.2). To do so, press the STOP button.
When the equipment switched itself off, turn back the pressure at the maintenance unit
in order to start the unit from a complete stop. Release the STOP button afterwards.
Press the START button (pos. 1.1) again and set the previous pressure.
CAUTION!
When you set the
switch on the control
panel to „MANUAL“ and
“SPRAY”, a timer starts
in the control panel.
Now you have 3 minutes
to set the switch back to
“AUTOMATIC”. Other-
wise the unit will shut
off.
If this happens turn back
the pressure on the
regulator, push the start
button and set the previ-
ous pressure again.