Complete cleaning
7
Translation of the original operation manual
41
41
•303_208176_1004_en•ski
WARNING!
Parts of the hand can be crushed or cut while lowering the drum cover onto
the container edge.
Never hold parts of the body (finger, etc.) in the area of the container edge and
drum cover! Make sure that no clothing gets caught in this area or pulled into the
container!
➤
Let the system run dry.
Settings on the mixer (circulate - CLOSED)
➤
Turn levers on the external mixer:
➤
SPRAY (pos. 13.2) to “CLOSED”.
➤
FLUSH (pos. 13.3 A+B) to “CLOSED”.
➤
CIRCULATE (pos. 13.1) to “CLOSED”.
➤
Turn the air regulator (pos. 2.2) of the main pump back to 0 bar.
➤
Press the STOP button (pos. 1.2) on the control panel.
➤
Close the air cut-off ball valve (pos. 2.1) on the maintenance unit.
Result: All of the material was removed from the system. The unit is prepared
for a longer pause. All air regulators were turned down and all shut-off valves
were closed. All accessory equipment were turned off and the power supply is
disconnected.