Translation of the original Operation Manual
11-3
•1307_PU280_SV1018DV1020_BAoDB_en•ski
en
Optional equipment
3.
Stop circulation
Close ball valves as soon as bubble-free, noiseless material
starts to run out.
Spray Gun
Feed Pump
Proportioner Pump
6 bar
/ 87 psi
6 bar
/ 87 psi
3 bar
/ 43,5 psi
Adjust the desired spraying pressure!
Figure 11.3
The silicagel filter is a moisture filter for installation in the drum lid of the Iso com
-
ponent.
➤
If humidity saturation is reached, granulate colour changes from orange to col
-
ourless. For the filter to function properly, the granulate needs to be regularly
dried
(Figure 11.6) - (Figure 11.7)
.
➤
During operation, the ball valve on the silicagel filter must be opened. Only
close the ball valve during longer downtimes, to prevent humidity from enter
-
ing through the filter
(Figure 11.5).
Version without return flow
Version with return flow
Figure 11.4
11.2
Silicagel filter
Summary of Contents for DUOMIX PU280
Page 68: ......