Translation of the original Operation Manual
11-8
•1307_PU280_SV1018DV1020_BAoDB_en•ski
en
Optional equipment
➤
Before operation check the correct use of the spray gun:
➤
Spray pattern regulating valve for spraying fog
➤
Front cap for leakages.
➤
the rear seals in the nut for leakages,
(Figure 11.14)
. Tighten the nut only
so far, that leakages are eliminated. Do not overtighten.
Figure 11.13
1.
Open the material valves
2.
Open the air pressure
valve
3.
Pull the trigger
4.
Adjust spray jet regulat
-
ing screw
Figure 11.14
1.
Release the trigger
2.
Connect the material
valves to the connection
block
3.
Remove possibly adher
-
ing material plugs by
pulling the trigger once
again
4.
Close the air pressure
valve
Figure 11.15
11.3.5 Check spray
gun
1
1
/
2
revolutions
11.3.6 Start spraying
1
1
/
2
revolutions
11.3.7
End spraying
Summary of Contents for DUOMIX PU280