4.
Screw out the locking tappet (pict. 5.6, pos. 1) and remove the needle
(pict. 5.6, pos. 2).
5.
Using a 6 mm open-end wrench, loosen the needle carrier (pict. 5.1.5,
pos. 2) while holding the needle back piece (Bild 5.1.5, Pos. 3).
6.
Adjust the needle.
turn needle clockwise
less atomizing air
turn needle counter clock-
wise
more atomizing air
7.
Secure the needle by tightening the needle carrier while holding the
needle back piece.
8.
Install the needle in the gun body and tighten the locking tappet securely.
Work interruptions
➤
Lock the lever (Fig 5.1) at each work interruption, regardless how short.
➤
Flush the spray gun thoroughly with the appropriate solvent immediately
after work is complete and at longer work interruptions. Flushing is com-
plete when clean solvent comes out of the gun.
Take care to use only acid-free solvent!
Translation of the original operation manual
25
SPAC_Optima2100_1302_en • 0550012 • jw