55
3.4.3.1.5 Fast-Moving
It must calibrate the depth of field firstly before using, according the calibration of depth of field to calculate the
object's moving speed. If the speed is higher than the warning speed, trigger alarm. (Trigger speed depends on
the sensitivity, the sensitivity range from 1 to 10, which means the moving speed from 10m/s to 1m/s).
Application scene
: it can only be applied to the scene where sparse target and no obvious occlusion. It is better
to install the camera above of the monitor area, and also the direction of the optical axis is perpendicular to the
direction of the moving object.
The config steps are shown as follows:
Step 1
,
Select rule type as “Fast-Moving” and the config interface is shown in Figure 3.4-15:
Figure 3.4-15 Fast-Moving
Step 2
, Click
to draw rules in the monitoring image.
Step 3
, Configure parameter info according to the actual needs. Please refer to Table 3.4-11 for more details.
Parameter
Description
Sensitivity
Set the trigger sensitivity, the value range is from 1 to 10, default is 5.
Table 3.4-11 Fast-Moving Parameter Description
Please refer to “
” for more details about other parameters.
Step 4
, Click
to complete config.
3.4.3.1.6 Parking Detection
The system determines whether the target is stationary or not, according to the tracking information. When the
rest time exceeds the set time, trigger alarm.
The config steps are shown as follows:
Step 1
,
Select rule
type as “Parking Detection” and the config interface is shown in Figure 3.4-16: