WIZ127SR User’s Manual
12
Its response format is like below.
<S[Option]>
[Option] : Server’s IP address in a dotted decimal format
ex) <RT>
Response
<S1>
WU
Format
<WU[y]>
Meaning
Set Whether DNS service will be allowed
[y] = 0 : Not use
[y] = 1 : Use
ex) <WU1>
Response
<S>
RU
Format
<RU>
Meaning
Get whether DNS mode is enabled or not
Its response format is like below.
<S[flag]>
[flag] : 0 = Not Use, 1 = Use
ex) <RU>
Response
<S
1
>
WE
Format
<WE[ch][ch][ch]>
Meaning
Set character string using for Software trigger in order to enter
serial command mode.
[ch] is a ASCII character represented in its hexadecimal format. For
example, if user wants use ‘A’ as [ch] then user should input its
ASCII code in hexadecimal format, ‘4’ and ‘1’, not ‘A’.
ex)If character string for software trigger is “+++” then
<WE2B2B2B>
Response
<S>
RE
Format
<RE>
Meaning
Get the current character string for software trigger to enter the
serial command mode.
Its response format is like below.
<S[ch1][ch2][ch3]>
[IP Addr] : Server’s IP address in a dotted decimal format
ex) <RE>
Response
<S2B2B2B>
WX
Format
<WX[IP Addr]>
Meaning
Set Server’s IP address to connect when the data socket is defined
as Client mode or Mixed mode. If user defined the data socket as a
Server mode, WIZ127SR don’t care this Server’s IP address.
[IP Addr] : Server’s IP address in a dotted decimal format
ex) <WX192.168.11.144>
Response
<S>
RX
Format
<RX>
Meaning
Get the current Server’s IP address