100
User Manual WMF 1100 S
Messages and instructions | Error messages and malfunctions
Error
number
Error
description
Action instructions
163
Flow error:
warm rinsing
Between each of the following steps switch off the coffee machine and on
again. If error not remedied carry out the next step.
Clean the brewing unit
w
Care
w
Clean the brewing unit, page 84
If error not remedied call WMF Service
186
Steam boiler:
level
Beverage dispensing temporarily blocked.
Check that grounds container is correctly inserted
Switch the coffee machine off and on again
Check whether the water tank is filled
188
Heating error:
over-temperature
Switch off the coffee machine, disconnect mains
plug
Call WMF Service
189
Steam boiler:
heat-up time error
Switch the coffee machine off and on again
If error not remedied call WMF Service
9083 Cooler temperature
is in the frost range
Check whether the cooler temperature is set
too low
9516
9517
Right grinder
blocked
Left grinder
blocked
Switch off the coffee machine
Disconnect mains plug
Remove bean hopper cover
Empty bean hoppers
Rotate the grinder disk clockwise or counter
clockwise only by using the multitool for
the hopper (two pins must be inserted in the
corresponding recesses on the grinder; see
illustration) until the blockage is cleared
Fill bean hoppers
Replace bean hopper cover
Switch on the coffee machine
w
Care
w
Clean the bean hopper, page 90
If the blockage cannot be cleared:
Set grinding degree one stage coarser
w
Other settings
w
Set grinding degree, page 71
If error not remedied call WMF Service