128
User Manual WMF 1300 S
Appendix: Technical data
It may be necessary to also observe additional country-specific regulations.
The customer's on-site electrical system must be designed to meet country-
specific regulations per IEC 60364 and must match the information on the
rating plate.
An isolated ground socket or a country-specific single-phase socket for
single-phase connection, or a 5-pole CEE / CEKON socket per DIN EN 50310
VDE 0800–2-310 or a country-specific multi-pole socket for a three-phase
connection, must be available near the machine. The sockets are part of the
customer‘s on-site installation. The power cord must not come into contact with
hot surfaces. If the power cord for this device is damaged then it must be replaced
by our service personnel or a similarly qualified person, in order to prevent hazards.
In order to avoid possible faults from arising in our shielded data lines due to
potential equalization currents between the devices, an additional potential
equalization unit should be planned for devices connected to the vending system
(see DIN EN 50310 VDE 0800–2-310).
If the machine is intended to be installed in a large kitchen, it is recommended
that it be equipped with a ground potential bonding conductor. The potential
equalization terminal is installed by WMF Service when needed.
CAUTION
Risk of fire and electric shock. Replace only with
manufacturer´s cord set, please see spare parts list.
(33 2402 5100)
Summary of Contents for 1300 S
Page 1: ...USER MANUAL NORTH AMERICA ENGLISH WMF 1300 S ...
Page 21: ...21 User Manual WMF 1300 S ...
Page 135: ...135 User Manual WMF 1300 S ...