Water filter
Options:
•
active
•
inactive
Default value:
inactive
active Water filter is fitted. Capacity and water
hardness are queried.
Measured carbonate hardness
Enter the measured water hardness in °dKH here.
Request drinking water hardness reading from
water supplier, or determine using WMF carbonate
hardness test (complete with instructions) in the
accessories
The carbonate hardness test is supplied with the
accessories.
If the machine is run with the wrong water
hardness setting, this can lead to severe lime
buildup and thus to leaking valves.
No liability is assumed for any resulting damage.
Measured total hardness
Enter the measured total hardness.
Filter capacity
Enter the filter capacity in litres here.
Water filter
DS_04_10_04
note
If the water hardness is between
0 and 5 °dKH, no water filter is
needed.
For coffee machines with a constant
water supply, we recommend using
the AquaBasic water filter.