Appendix: Technical data
The local power supply must be constructed according to
IEC 364. To improve safety, the coffee machine should be
fitted with an FI 30 mA earth leakage current circuit breaker
complying with EN 61008. Near the device or about 30 cm
below the counter top there should be a shockproof socket
as a single-phase connection installed locally on the rear or
side wall of the counter substructure or a country-specific
single-phase socket. If the mains cable for this device is
damaged then it must be replaced by our service personnel
or a similarly qualified person, in order to prevent hazards.
A separator switch is recommended for a flexible connection.
The mains cable must not come into contact with hot
surfaces. The mains switch and plug top are part of the
customer‘s on-site installation. The machine may not be
fitted with a fixed permanent mains connection if installed on
a transporting trolley (a mobile station).
In order to avoid possible faults from arising on our shielded
data lines due to potential equalization currents between
the devices, an additional potential equalization unit should
be planned for devices connected to the vending system.
(See EN 60309)