26
WMF 2000 S Service Manual Edition 11/2010
WMF 2000 S Service Manual
Re
po
rt
D
is
pl
ay
D
es
cr
.
En
tr
y
ri
ng
m
em
.
En
tr
y
di
sp
la
y
Co
m
m
en
t
N
o.
m
al
fu
nc
ti
on
m
em
or
y
130 F130 General current
malfunction
√
√ Short circuit if
immediately at
switching-on
24/30 V present
28
not implemented
149 F149 General voltage
malfunction
√
√ If short circuit is present
in 24/30 V systems
86
161 F161 flowmeter
malfunction during
brewing
√
√
241
162 F162 flowmeter
malfunction during
cleaning
√
√
242
163 F163 flowmeter
malfunction during
checking
√
√
243
164 F164 flowmeter
malfunction during hot
water dosage
√
√
244
165 F165 flowmeter
malfunction during choc
dosage
√
√
245
166 F166 flowmeter
malfunction during DK
feeding
√
√
246
167 F167 flowmeter
malfunction during
descaling
√
√
167
170 F170 Automatic steam
wand sensor short cut
√
√
336
171 F171 Automatic steam
wand sensor interruption
/ not connected
√
√
335
186 F186 timeout during
steam boiler filling
√
√
247
187 F187 Steam boiler sensor
damage
√
√