27
WMF 2000 S Service Manual Edition 11/2010
WMF 2000 S Service Manual
Re
po
rt
D
is
pl
ay
D
es
cr
.
En
tr
y
ri
ng
m
em
.
En
tr
y
di
sp
la
y
Co
m
m
en
t
N
o.
m
al
fu
nc
ti
on
m
em
or
y
188 F188 Excess temperature
in steam boiler
√
√
231
189 F189 Heating-time steam
boiler
√
√
43
9061 Standby Event
√
Coming and going
61 Coming and going
9062 Reset Event!
√
Coming and going
62
9104 Timer function not
possible
√
√ Machine cannot switch
off due to cleaning in
progress
9104
Fifo was deleted
√
√
9118
Defaults into RAM
√
√
9119
Defaults into flash
√
√
9120
Machine cleaning in
progress
√
internal
9125 internal
Milk foam cleaning in
progress!
√
internal
9126 internal
Cleaning was interrupted
√
√ due to an error in the
cleaning program
9136 Display cleaning
obligation
Mixer cleaning in progress √
internal
9180
AD-transformer ready!
(for developers only)
√
√ internal
9236
9248 Malfunction in level
sensor
√
√
9248
9256 Auto detect malfunction:
Right grinder not
detected
√
√
9256
9257 Auto detect malfunction:
brewing-valve not
detected
√
√
9257
9258 Auto detect malfunction:
Oscillating pump not
detected
√
√
9258
9259 Auto detect malfunction:
Release valve not
detected
√
√
9259
9269 Auto detect malfunction:
Fan not detected
√
√
9260