31
WMF 2000 S Service Manual Edition 11/2010
WMF 2000 S Service Manual
8.2
Setting pressure reducer
Setting pressure reducer without laptop
Start service program
service routine
setting
pressure reducer
start.
Remove screw-cap on water tank filler.
Screw auxiliary nipple to accept plug-in connector into
the water tank filler
Mount auxiliary tool on filler.
Press field
Start
Supply valve opens
Read pressure on pressure gauge.
Set pressure to 1.8 bar at pressure reducer.
Finish test (machine is turned off).
Dismantle setting equipment and remove auxiliary
nipple.
Replace filler cap.
Setting pressure reducer with KonfigTool
Adjust test environment
set pressure reducer
start
Remove filler screw-cap
Screw auxiliary nipple to accept plug-in connector into
the water tank filler.
Mount auxiliary tool on filler.
Start test on laptop
Supply valve opens
Read pressure on pressure gauge.
Set pressure to 1.8 bar at pressure reducer.
Finish test
Dismantle setting equipment and remove auxiliary
nipple.
Replace filler cap.